In the realm of wastewater management, Rusukh Specialized Company stands at the forefront with its cutting-edge product, the Rusukh Lint Trap. Designed to tackle sediment, sand, and lint accumulation, this ingenious solution prevents clogging in plumbing systems and ensures smooth wastewater flow. With a commitment to quality and innovation, Rusukh has established itself as a leading provider of specialized engineering services in the Kingdom of Saudi Arabia. In this comprehensive article, we will explore the features, benefits, installation considerations, and maintenance guidelines for the Rusukh Lint Trap, shedding light on its remarkable capabilities in the realm of wastewater management.

Uniform Plumbing Code (UPC)

  • The RSK-LT lint traps are completely weatherproof and are intended for separating sediment, sand and lint from wastewater.
  • The raw materials used are stainless steel or iron coated with epoxy (acidifier), which ensures high mechanical resistance and corrosion protection.
  • The production of equipment under controlled conditions, the use of high-quality raw materials and the inspection of the final product, in accordance with the requirements of the ISO 9001 standard, guarantee the quality of the final product.

 

Engineering Specification

The Importance of Wastewater Management

1.1 Understanding the Challenges

The accumulation of sediment, sand, and lint in wastewater can lead to clogging in plumbing systems.

Clogged drains can cause disruptions in daily activities, increase maintenance costs, and pose health risks.

1.2 The Role of Lint Traps

Lint traps are essential components in plumbing systems that intercept and capture lint, preventing it from entering drain lines.

By installing lint traps, potential clogging issues can be mitigated, ensuring the smooth flow of wastewater.

Applications

The RSK-LT lint traps are specifically designed for wastewater generated in laundries, where lint and sand particles can cause drainage system blockages and interfere with sewage treatment processes. By installing RSK-LT lint traps in these settings, the separation of sediment, sand, and lint from wastewater can be efficiently achieved, ensuring optimal performance of the drainage system.

Advantages

  1. Heavy-duty materials: RSK-LT lint traps are constructed using robust materials, guaranteeing durability and longevity.
  2. Protection cover with non-odor safety: The lint traps feature a protective cover that ensures safety and prevents unpleasant odors from escaping.
  3. High storage capacity for separated products: With ample storage capacity, the lint traps can effectively hold separated sediment, sand, and lint.
  4. High mechanical resistance and corrosion protection: The utilization of high-quality materials provides excellent mechanical strength and protection against corrosion.
  5. Easy installation and maintenance: RSK-LT lint traps are designed for easy installation and require minimal maintenance, making them user-friendly.
  6. Total watertightness: The traps are fully watertight, preventing leakage and ensuring efficient operation.
  7. Power consumption-free: RSK-LT lint traps operate without the need for any power consumption, contributing to energy efficiency.
  8. Cost-effective: These lint traps offer a cost-effective solution for efficient sediment separation in wastewater.
  9. Odorless with proper ventilation: The lint traps, when combined with appropriate ventilation, eliminate odors effectively.
  10. Available in two materials: RSK-LT lint traps are available in two material options, stainless steel (304 L / 316 L) and acid-resistant epoxy-coated steel, providing flexibility and suitability for different applications.

 

Introducing the Rusukh Lint Trap

2.1 Design and Operation

The Rusukh Lint Trap is meticulously designed to remove sediment, sand, and lint from wastewater, guaranteeing uninterrupted flow.

The trap employs successive barriers to capture suspended materials and prevent their passage.

Properly located and maintained lint traps significantly reduce lint buildup in drain systems, averting potential clogs.

2.2 Sizing and Capacity

The Rusukh Lint Trap's size is determined by the number of washing machines it serves.

Sizing criteria, such as retention time and storage factors, adhere to industry standards like the Uniform Plumbing Code (UPC).

Unveiling Rusukh Specialized Company

3.1 Company Overview

Rusukh Specialized Company is a renowned provider of specialized engineering services in the Kingdom of Saudi Arabia.

With a commitment to quality, innovation, and customer satisfaction, Rusukh has earned a reputable position in the industry.

3.2 Commitment to Quality Materials

Rusukh utilizes high-quality materials for the construction of its lint traps.

Stainless steel variants, such as 304L and 316L, are employed for their excellent corrosion resistance and stability.

Acid-resistant epoxy-coated steel, both internally and externally, ensures durability and longevity.

Installation Considerations

4.1 Optimal Placement

The Rusukh Lint Trap should be installed as close as possible to the fixture or fitting it serves.

Various installation options, including floor placement, partial enclosure, flush installation, or complete recessing, cater to different structural and piping requirements.

4.2 Space and Accessibility

Sufficient space must be allocated to facilitate easy trap cover removal for regular maintenance and cleaning.

Installation locations should avoid long piping lengths, exceeding 25 feet, to optimize trap performance.

4.3 Flow Control Fittings

Flow control fittings play a vital role in maintaining the Rusukh Lint Trap's efficiency.

These fittings regulate the flow rate of wastewater, preventing overload and ensuring maximum pollutant retention.

Proper connection of flow control fittings to the vent stack or vent is crucial for enhanced efficiency.

 

Flow control fittings ensure 90% or more retention efficiency of the interceptor.

When consideration isn’t given to the flow rate of the waste water to be handled, the actual flow rate through the interceptor usually exceeds its rated maximum.

With such flow rate, the interceptor would be overloaded. Retention time within the unit would not be sufficient for maximum separation.

The result would be low efficiency, and pollutants left in the waste water would pass through the interceptor, making the installation less than effective.

When the flow is controlled by use of a flow control fitting so that it can never exceed the maximum rating of the interceptor, and the interceptor is cleaned on a regular basis, the maximum pollutant retention efficiency will be achieved and maintained.

All flow control fittings are built with an air intake and should be connected to the vent stack or vent not lower than the flow level of the highest drain serviced or terminated in a return bend at the same elevation outside of the building.

A vented flow control fitting improves the efficiency of the grease interceptor by introducing air into the body of the interceptor.

NO HUB PIPE

CONNECTION SIZE

ORIFICE SIZE

VENT CONNECTION

SIZE

2” (52)

0.375” (9)

2” (50)

2” (52)

0.500” (13)

2” (50)

2” (52)

0.656” (16)

2” (50)

2” (52)

0.750” (19)

2” (50)

3” (75)

1.000” (25)

2” (50)

3” (75)

1.250” (31)

2” (50)

3” (75)

1.250” (31)

2” (50)

3” (75)

2.000” (50)

2” (50)

4” (102)

2.000” (50)

2” (50)

4” (102)

2.250” (57)

2” (50)

Ventilation Requirements

5.1 Importance of Ventilation

Ventilation is necessary to maintain a water seal within the trap and prevent excessive pressure buildup.

Ventilation holes in the lint trap comply with code requirements and contribute to its optimal functionality.

5.2 Vented Flow Control Fittings

Vented flow control fittings facilitate improved air circulation within the lint trap, enhancing its efficiency.

These fittings can be connected to the vent stack or terminated with a return bend outside the building to introduce air into the interceptor.

Maintenance Guidelines

6.1 Regular Cleaning

Regular maintenance is crucial to ensure the Rusukh Lint Trap's optimum operation.

Cleaning intervals should be based on the trap's capacity and the amount of lint in the wastewater.

Thorough inspection after cleaning guarantees unobstructed inlet, outlet, and air relief ports.

6.2 Proper Waste Disposal

Disposed waste material from the lint trap should never be introduced into drains, sewers, or natural bodies of water.

Appropriate disposal containers must be utilized to ensure environmental compliance and responsible waste management.

Conclusion

In the realm of wastewater management, Rusukh Specialized Company's Lint Trap emerges as a game-changer, tackling sediment, sand, and lint accumulation with remarkable efficiency. By implementing this innovative solution, plumbing systems remain free from clogs, ensuring uninterrupted wastewater flow. Rusukh's commitment to quality materials, meticulous design, and adherence to industry standards position their lint trap as a reliable and effective choice for customers in the Kingdom of Saudi Arabia and beyond. With proper installation, regular maintenance, and responsible waste disposal, the Rusukh Lint Trap stands as a beacon of excellence in the realm of wastewater management, revolutionizing plumbing systems for a cleaner and more efficient future.